Shop page iconDownload page icon

Choose your language

Amann production hall

Noise reduction in production hall 

Dachbauteile LIGNO® Akustik Q3 klassik sorgen in der Produktionshalle Amann dafür, dass es beim Einsatz von Maschinen nie zu laut in der Halle wird.
Die Deckenverkleidung mit breitem Leistenprofil sorgt dafür, dass es bei aller Betriebsamkeit nie zu laut in der Produktionshalle wird.
In Produktionshallen sind die Arbeiter den ganzen Tag einem hohen Geräuschpegel ausgesetzt. Dafür dass dieser nicht Überhand nimmt, sorgen die Dachbauteile LIGNO® Akustik Q3 klassik mit integriertem Akustikabsorber.

Traditional timber construction knowledge and decades of practice have allowed the Black Forest company Holzbau Amann to grow from a regional carpentry company to an internationally operative expert for structural timber construction. In order to translate customers‘ ideas into the most economical and creatively meaningful timber construction, the company is investing in state-of-the-art CAD and joinery technology. An important component of this way of working is the new production hall, in which LIGNO® roof components ensure that it never gets too loud despite all the hustle and bustle. A very environmentally friendly construction project, too, because long transport routes are eliminated: Holzbau Amann and Lignotrend are direct neighbours in Weilheim-Bannholz!  

Configuration overview

Components used

  • LIGNO® Akustik Q3 klassik  |  Roof component

    Produktkode: LIGNO® Akustik Q klassik_Q3_150-210_rg0_s0_k50l_p0_al40g_625-95-30_WTE_gb_b0
     
    Installation top


    Whether the element is open or closed at the top is determined by the area of application. If, for example, the element is to be filled with fill on site as a storey ceiling or roof terrace (LIGNO® Rippe Q3-x), its cavities are open at the top (feature _r0). To guide pipes at the top of the element, a cross grid (_r25, _r50) can be added to some superstructures. For roof superstructures, there is usually a flat closed finish _rg0 (LIGNO® Block Q-x, LIGNO® Block Q3-x or corresponding versions of LIGNO® Acoustic classic).

    Installation top

    _rg0 Closed, without cross grid

    Statics


    The height of the load-bearing webs of the element is variable and determined according to static requirements from load and span. Within the framework of this configurator, the selection is limited to four height ranges. A more precise definition is made later during pre-dimensioning or verification with the LTB-x calculation programme. Bulk volume and/or necessary space for installations can also be decisive for the height.

    Statics

    _150-210 Small span

    Fire resistance


    If fire protection is required, an additional layer is added below the web area (for elements with strip profiles _z26, _z53, _z80, for elements with board profiles Akustik klassik _k50g). Their height determines the fire resistance duration of the cross-section from 30 to 90 minutes. The fire resistance must be statically verified. If there are no requirements, the standard versions _z0 or _k50l are to be selected.

    Fire resistance

    _k50l R0

    Cavity


    Panel designs with slat profiles and additional layer can be configured with an additional cavity (_p26, _p53) below the additional layer for installation guides, fixtures or to improve sound absorption. Cables laid there then do not penetrate the fire-protection layer. If required, the cavity is filled with insulating material (_p26mw, _p26ha) to improve acoustic absorption. If no cavity is necessary, the characteristic _p0 is selected.

    Cavity

    _p0 No cavity

    Room acoustics


    If the soffit of the element is to have a good sound-absorbing effect, the penultimate layer is configured as absorber _a50g. Otherwise, this layer is configured as a solid wood layer _a0.

    Room acoustics

    _al40g 40 % Absorber

    Profile


    The visible layer is profiled with joints. The code for profiling indicates in millimetres: Element width, strip width (rounded, from/to if applicable) and joint width (rounded) as well as a letter identification for variants, e.g. with chamfered strip edges or with additional height gradation.
     

    Note: Some profiles indirectly cause exclusions for other configuration options.

    Profile 

    _625-95-30 Slat profile

    Wood type


    Various wood species are available for the visible layer. For quality reasons, individual wood species cannot be configured for all profiles; for technical reasons, surface treatments are excluded for some wood species.

    Wood type

    _WTE Silver fir, economy

    Treatment


    Depending on the type of wood, the optional application of a surface treatment is possible ex works. Individual colour finishes are always sampled for coordination. For elements in individual lengths, colour treatment is limited to max. 5 m length.

    Treatment

    _b0 Untreated

    Structure


    The face is subjected to a brushing _gb as standard, which produces a stronger or weaker structure depending on the type of wood and makes the surface less sensitive to scratches. Alternatively, a smooth sanding _gs can be carried out, or on request a bandsaw cut _grimitated.

    Structure

    _gb Brushed

Reference-related

Downloads

Project participants

  • Holzbau Amann GmbH

    Execution

    Albtalstraße 1
    79809 Weilheim

    www.holzbau-amann.de

  • GRANACHER

    Photographer

    Hofwiese 10
    79809 Weilheim

     

    www.simplexxx.de

  • Related references

      Production hall of 
      Lamello AG 

      The products that the Lamello company manufactures stand for quality, innovation and...

      4416 CH-Bubendorf 

      View
        Dachscheibe mit Akustikprofil für die Produktionshalle von Lamello in Bubendorftitletitletitletitle

      New Fair Hall Hamburg 

      No fear of big challenges: The roof areas of the Hamburg exhibition halls were made with Lignotrend...

      20357 Hamburg

      View
        An dieses Großprojekt wurden hohe Anforderungen, z.B. bezüglich Brandschutz und Raumakustik gesetzt, welche die eingesetzten LIGNO® Akustik Q3 klassik erfüllen. Die Dachausstattung mit LIGNO® Akustik Q3 klassik zeigt sich innen durch eine edle Holzoberfläche, welche zugleich hohe Brandschutz -und Raumakustik Anforderungen erfüllt. Die Dachfläche der Messehallen Hamburg wurde als Tonnendach mit Lignotrend-Elementen ausgestattet, deren Sichtseite im Inneren in ästiger Fichte erscheint.Die Messegebäude müssen eine Vielzahl an Anforderungen, wie hoher Brandschutz, optimierte Raumakustik oder hohe Flexibilität erfüllen, welche unter anderem durch den Einsatz von LIGNO® Akustik Q3 klassik gelingt.