Renovation indoor swimming pool WASSER:WERK
Family pool and sports pool in one
During the renovation of the Waldshut-Tiengen town hall from the 1970s, the existing building was gutted, a foyer was added and the halls were made usable for cultural and sporting events. For the extension of the swimming hall, the massive concrete ceiling construction was continued in the form of filigree fair-faced concrete beams. Genuine timber acoustic panels arranged in wave form in between provide for dynamics and show: Wood in an indoor swimming pool is a good choice!
Configuration overview
Components used
LIGNO® Acoustic light | Ceiling cladding
Produktkode: LIGNO® Acoustic light 3S_33_a70g_625-12-4_WTL-i_gb_b0Wood type
Various wood species are available for the visible layer. For quality reasons, individual wood species cannot be configured for all profiles; for technical reasons, surface treatments are excluded for some wood species.Wood type
_WTL-i Silver fir knotless, patterned
Profile
The visible layer is profiled with joints. The code for profiling indicates in millimetres: Element width, strip width (rounded, from/to if applicable) and joint width (rounded) as well as a letter identification for variants, e.g. with chamfered strip edges or with additional height gradation.
Note: Some profiles indirectly cause exclusions for other configuration options.Profile
_625-12-4 Slat profile
Structure
The face is subjected to a brushing _gb as standard, which produces a stronger or weaker structure depending on the type of wood and makes the surface less sensitive to scratches. Alternatively, a smooth sanding _gs can be carried out, or on request a bandsaw cut _grimitated.Structure
_gb Brushed
Treatment
Depending on the type of wood, the optional application of a surface treatment is possible ex works. Individual colour finishes are always sampled for coordination. For elements in individual lengths, colour treatment is limited to max. 5 m length.Treatment
_b0 Untreated
Room acoustics
If the soffit of the element is to have a good sound-absorbing effect, the penultimate layer is configured as absorber _a50g. Otherwise, this layer is configured as a solid wood layer _a0.Room acoustics
_a70g 70% Absorber
Fire behaviour
Few configurations can be configured with a flame-retardant surface. This may result in a modified element structure, greater thickness or the need for measures in the area of the substructure.Fire behaviour
_B-s2-d0 Fire retardant surface
Reference-related
Downloads
Project participants
Stadtwerke Waldshut-Tiengen GmbH
S4 Architekten Michael Duffner, Henning Musahl, Gerold Müller, Ernesto Preiser
DUFFNER ARCHITEKTEN BDA
Kalvarienbergstraße 1 a
79761 Waldshut-Tiengen
architekturbüro henning musahl
Untere Haspelstraße 36
79761 Waldshut-Tiengen
Architekturbüro Gerold Müller
Im Hasli 12
79761 Waldshut-Tiengen
www.gerold-mueller-architekt.de
ARCHITEKT PREISER
Daimlerstr. 15
79761 Waldshut-Tiengen
Schreinerei Tomasi
Rudolf-Diesel-Straße 12
79761 Waldshut-Tiengen
www.schreinerei-tomasi.de
Foto & Design Gröber GmbH & Co.KG
Related references
Panorama Spa in the indoor pool
In the newly created bathing hall at the Bio-Seehotel Zeulenroda, the architects of the...
07937 Zeulenroda
ViewIndoor swimming pool
„De IJsselslag“
Due to poor acoustics, noise is quickly generated in indoor swimming pools, which can...
7204 NL-Zutphen
View