Canteen of École Voltaire in Berlin
Architecture à la carte
The urban development requirements of the 21st century - fast construction, lightweight building materials, sustainability, healthy living and CO2 reduction - make wood the building material of the present. Nevertheless, buildings in which both the structure and the building envelope are made of wood are not yet the norm in the urban context. Martin Schmitt - architect and trained carpenter - has now realised such a building in the middle of Berlin. For the roof construction of the school canteen in timber frame construction, LIGNO® Block Q3 Acoustic, which are cross laminated timber box elements from Lignotrend play a more than supporting role: The multifunctional, dimensionally stable overall packages combine statics, sound insulation, finished timber appearance and room acoustics.
Configuration overview
Components used
LIGNO® Block Q3 | Roof component
Product code: LIGNO® Block Q3_310-450_rg0_sze_z26_p53_a50g_625-12-4_WTL_gb_b0Installation top
Whether the element is open or closed at the top is determined by the area of application. If, for example, the element is to be filled with fill on site as a storey ceiling or roof terrace (LIGNO® Rippe Q3-x), its cavities are open at the top (feature _r0). To guide pipes at the top of the element, a cross grid (_r25, _r50) can be added to some superstructures. For roof superstructures, there is usually a flat closed finish _rg0 (LIGNO® Block Q-x, LIGNO® Block Q3-x or corresponding versions of LIGNO® Acoustic classic).Installation top
_rg0 Closed, without cross grid
Statics
The height of the load-bearing webs of the element is variable and determined according to static requirements from load and span. Within the framework of this configurator, the selection is limited to four height ranges. A more precise definition is made later during pre-dimensioning or verification with the LTB-x calculation programme. Bulk volume and/or necessary space for installations can also be decisive for the height.Statics
_310-450 Large span
Fire resistance
If fire protection is required, an additional layer is added below the web area (for elements with strip profiles _z26, _z53, _z80, for elements with board profiles Akustik klassik _k50g). Their height determines the fire resistance duration of the cross-section from 30 to 90 minutes. The fire resistance must be statically verified. If there are no requirements, the standard versions _z0 or _k50l are to be selected.Fire resistance
_z26 REI 30 Fire resistance
Cavity
Panel designs with slat profiles and additional layer can be configured with an additional cavity (_p26, _p53) below the additional layer for installation guides, fixtures or to improve sound absorption. Cables laid there then do not penetrate the fire-protection layer. If required, the cavity is filled with insulating material (_p26mw, _p26ha) to improve acoustic absorption. If no cavity is necessary, the characteristic _p0 is selected.Cavity
_p53 53mm Height
Room acoustics
If the soffit of the element is to have a good sound-absorbing effect, the penultimate layer is configured as absorber _a50g. Otherwise, this layer is configured as a solid wood layer _a0.Room acoustics
_a50g Integrated absorber
Profile
The visible layer is profiled with joints. The code for profiling indicates in millimetres: Element width, strip width (rounded, from/to if applicable) and joint width (rounded) as well as a letter identification for variants, e.g. with chamfered strip edges or with additional height gradation.
Note: Some profiles indirectly cause exclusions for other configuration options.Profile
_625-12-4 Slat profile
Wood type
Various wood species are available for the visible layer. For quality reasons, individual wood species cannot be configured for all profiles; for technical reasons, surface treatments are excluded for some wood species.Wood type
_WTL Silver fir knotless, patterned
Structure
The face is subjected to a brushing _gb as standard, which produces a stronger or weaker structure depending on the type of wood and makes the surface less sensitive to scratches. Alternatively, a smooth sanding _gs can be carried out, or on request a bandsaw cut _grimitated.Structure
_gb Brushed
Treatment
Depending on the type of wood, the optional application of a surface treatment is possible ex works. Individual colour finishes are always sampled for coordination. For elements in individual lengths, colour treatment is limited to max. 5 m length.Treatment
white varnish (on site)
Reference-related
Downloads
Project participants
Martin Schmitt Architektur / Kommunikation im Raum
Walter Kastor GmbH & Co. KG
Alte Mainzer Straße 24
55430 Oberwesel
www.holzbau-kastor.de
Axel Hartmann Fotografie
Related references
Mosaik - Workshops for the disabled
In addition to a public forecourt, the shingle-clad workshop building has a...
10999 Berlin
ViewLargest school in France
No one misses the new school complex at the centre of the revitalised Pasteur district of Limeil-Brévannes...
94450 FR-Limeil-Brévannes