New Fair Hall Hamburg
No fear of big challenges
Around 100,000 square metres of roof area of the Hamburg exhibition halls were designed as barrel roofs with Lignotrend elements, some of which absorb enormous disc forces. Fire protection and room acoustics were also quite demanding in this construction project. The design of the halls themselves follows a modular principle of arrangement, which guarantees high flexibility as well as largely natural ventilation and the supply of daylight.
Configuration overview
Components used
LIGNO® Acoustic Q3 classic | Roof component
Product code: LIGNO® Acoustic Q classic_Q3_150-210_rg0_s0_k50l_p0_al40g_625-105-20_FI-ä_gb_b-xyInstallation top
Whether the element is open or closed at the top is determined by the area of application. If, for example, the element is to be filled with fill on site as a storey ceiling or roof terrace (LIGNO® Rippe Q3-x), its cavities are open at the top (feature _r0). To guide pipes at the top of the element, a cross grid (_r25, _r50) can be added to some superstructures. For roof superstructures, there is usually a flat closed finish _rg0 (LIGNO® Block Q-x, LIGNO® Block Q3-x or corresponding versions of LIGNO® Acoustic classic).Installation top
_rg0 Closed, without cross grid
Statics
The height of the load-bearing webs of the element is variable and determined according to static requirements from load and span. Within the framework of this configurator, the selection is limited to four height ranges. A more precise definition is made later during pre-dimensioning or verification with the LTB-x calculation programme. Bulk volume and/or necessary space for installations can also be decisive for the height.Statics
_150-210 Low span
Fire resistance
If fire protection is required, an additional layer is added below the web area (for elements with strip profiles _z26, _z53, _z80, for elements with board profiles Akustik klassik _k50g). Their height determines the fire resistance duration of the cross-section from 30 to 90 minutes. The fire resistance must be statically verified. If there are no requirements, the standard versions _z0 or _k50l are to be selected.
Fire resistance
_z0 R0
Cavity
Panel designs with slat profiles and additional layer can be configured with an additional cavity (_p26, _p53) below the additional layer for installation guides, fixtures or to improve sound absorption. Cables laid there then do not penetrate the fire-protection layer. If required, the cavity is filled with insulating material (_p26mw, _p26ha) to improve acoustic absorption. If no cavity is necessary, the characteristic _p0 is selected.Cavity
_p0 No cavity
Room acoustics
If the soffit of the element is to have a good sound-absorbing effect, the penultimate layer is configured as absorber _a50g. Otherwise, this layer is configured as a solid wood layer _a0.Room acoustics
_k50l Integrated absorber
Profile
The visible layer is profiled with joints. The code for profiling indicates in millimetres: Element width, strip width (rounded, from/to if applicable) and joint width (rounded) as well as a letter identification for variants, e.g. with chamfered strip edges or with additional height gradation.Note: Some profiles indirectly cause exclusions for other configuration options.
Profile
_625-105-20 Slat profile
Wood type
Various wood species are available for the visible layer. For quality reasons, individual wood species cannot be configured for all profiles; for technical reasons, surface treatments are excluded for some wood species.
Wood type
_FI-ä Spruce with knots, A quality
Treatment
Depending on the type of wood, the optional application of a surface treatment is possible ex works. Individual colour finishes are always sampled for coordination. For elements in individual lengths, colour treatment is limited to max. 5 m length.Treatment
_b-xy Individual colour treatment
Structure
The face is subjected to a brushing _gb as standard, which produces a stronger or weaker structure depending on the type of wood and makes the surface less sensitive to scratches. Alternatively, a smooth sanding _gs can be carried out, or on request a bandsaw cut _grimitated.Structure
_gb Brushed
Reference-related
Downloads
Project participants
ingenhoven architects GmbH
Plange Mühle 1
40221 Düsseldorf
Holzbau Amann GmbH
Albtalstraße 1
79809 Weilheim
www.holzbau-amann.de
Frank Herlet
Related references
Production hall of
Lamello AG
The products that the Lamello company manufactures stand for quality, innovation and...
4416 CH-Bubendorf
ViewThree-field sports hall
A certain level of loudness in the sports environment underlines the special atmosphere of...
01157 Dresden
View