Choose your language

Schule am Kiefernwäldchen

Learning in the treetops 

Three compact “tree houses” blend into the woods and are grouped around a playground. The connection is made with footbridges on the outside. It goes without saying that good room acoustics are a top priority for a speech therapy school: The acoustically effective surfaces of the floor components and the walls clad with acoustic panels ensure this and give the rooms a comfortable quality of stay.

Configuration overview

Components used

  • LIGNO® Rippe Q3  |  Ceiling component

    Product code: LIGNO® Rippe Q3_310-450_r0_s0_z26_p26_a50g_625-12-4_WTL_gb_buv
    Installation top


    Whether the element is open or closed at the top is determined by the area of application. If, for example, the element is to be filled with fill on site as a storey ceiling or roof terrace (LIGNO® Rippe Q3-x), its cavities are open at the top (feature _r0). To guide pipes at the top of the element, a cross grid (_r25, _r50) can be added to some superstructures. For roof superstructures, there is usually a flat closed finish _rg0 (LIGNO® Block Q-x, LIGNO® Block Q3-x or corresponding versions of LIGNO® Acoustic classic).

    Installation top

    _r0 Open, without cross grid

    Statics


    The height of the load-bearing webs of the element is variable and determined according to static requirements from load and span. Within the framework of this configurator, the selection is limited to four height ranges. A more precise definition is made later during pre-dimensioning or verification with the LTB-x calculation programme. Bulk volume and/or necessary space for installations can also be decisive for the height.

    Statics 

    _310-450 Large span  

    Fire resistance


    If fire protection is required, an additional layer is added below the web area (for elements with strip profiles _z26, _z53, _z80, for elements with board profiles Akustik klassik _k50g). Their height determines the fire resistance duration of the cross-section from 30 to 90 minutes. The fire resistance must be statically verified. If there are no requirements, the standard versions _z0 or _k50l are to be selected.

    Fire resistance

    _z26 REI 30 Fire resistance 

    Cavity


    Panel designs with slat profiles and additional layer can be configured with an additional cavity (_p26, _p53) below the additional layer for installation guides, fixtures or to improve sound absorption. Cables laid there then do not penetrate the fire-protection layer. If required, the cavity is filled with insulating material (_p26mw, _p26ha) to improve acoustic absorption. If no cavity is necessary, the characteristic _p0 is selected. 

    Cavity

    _p26 26 mm Height 

    Room acoustics


    If the soffit of the element is to have a good sound-absorbing effect, the penultimate layer is configured as absorber _a50g. Otherwise, this layer is configured as a solid wood layer _a0.

    Room acoustics

    _a50g 50 % Absorber 

    Profile


    The visible layer is profiled with joints. The code for profiling indicates in millimetres: Element width, strip width (rounded, from/to if applicable) and joint width (rounded) as well as a letter identification for variants, e.g. with chamfered strip edges or with additional height gradation. 

    Note: Some profiles indirectly cause exclusions for other configuration options.

    Profile 

    _625-12-4 Slat profile 

    Wood type


    Various wood species are available for the visible layer. For quality reasons, individual wood species cannot be configured for all profiles; for technical reasons, surface treatments are excluded for some wood species.

    Wood type

    _WTL Silver fir knotless, patterned 

    Structure


    The face is subjected to a brushing _gb as standard, which produces a stronger or weaker structure depending on the type of wood and makes the surface less sensitive to scratches.  Alternatively, a smooth sanding _gs can be carried out, or on request a bandsaw cut _grimitated.

    Structure

    _gb Brushed

    Treatment


    Depending on the type of wood, the optional application of a surface treatment is possible ex works. Individual colour finishes are always sampled for coordination. For elements in individual lengths, colour treatment is limited to max. 5 m length.

    Treatment

    _buv UV-protection stain 

  • LIGNO® Rippe Q3  |  Ceiling component

    Product code: LIGNO® Rippe Q3_230-290_r0_s0_z26_p26_a50g_625-12-4_WTL_gb_buv
    Installation top


    Whether the element is open or closed at the top is determined by the area of application. If, for example, the element is to be filled with fill on site as a storey ceiling or roof terrace (LIGNO® Rippe Q3-x), its cavities are open at the top (feature _r0). To guide pipes at the top of the element, a cross grid (_r25, _r50) can be added to some superstructures. For roof superstructures, there is usually a flat closed finish _rg0 (LIGNO® Block Q-x, LIGNO® Block Q3-x or corresponding versions of LIGNO® Acoustic classic).

    Installation top

    _r0 Open, without cross grid

    Statics


    The height of the load-bearing webs of the element is variable and determined according to static requirements from load and span. Within the framework of this configurator, the selection is limited to four height ranges. A more precise definition is made later during pre-dimensioning or verification with the LTB-x calculation programme. Bulk volume and/or necessary space for installations can also be decisive for the height.

    Statics

    _230-290 Medium span 

    Fire resistance


    If fire protection is required, an additional layer is added below the web area (for elements with strip profiles _z26, _z53, _z80, for elements with board profiles Akustik klassik _k50g). Their height determines the fire resistance duration of the cross-section from 30 to 90 minutes. The fire resistance must be statically verified. If there are no requirements, the standard versions _z0 or _k50l are to be selected.

    Fire resistance

    _z26 REI 30 Fire resistance 

    Cavity


    Panel designs with slat profiles and additional layer can be configured with an additional cavity (_p26, _p53) below the additional layer for installation guides, fixtures or to improve sound absorption. Cables laid there then do not penetrate the fire-protection layer. If required, the cavity is filled with insulating material (_p26mw, _p26ha) to improve acoustic absorption. If no cavity is necessary, the characteristic _p0 is selected. 

    Cavity

    _p26 26 mm Height 

    Room acoustics


    If the soffit of the element is to have a good sound-absorbing effect, the penultimate layer is configured as absorber _a50g. Otherwise, this layer is configured as a solid wood layer _a0.

    Room acoustics

    _a50g 50 % Absorberanteil 

    Profile


    The visible layer is profiled with joints. The code for profiling indicates in millimetres: Element width, strip width (rounded, from/to if applicable) and joint width (rounded) as well as a letter identification for variants, e.g. with chamfered strip edges or with additional height gradation. 

    Note: Some profiles indirectly cause exclusions for other configuration options.

    Profile 

    _625-12-4 Slat profile 

    Wood type


    Various wood species are available for the visible layer. For quality reasons, individual wood species cannot be configured for all profiles; for technical reasons, surface treatments are excluded for some wood species.

    Wood type

    _WTL Silver fir knotless, patterned 

    Structure


    The face is subjected to a brushing _gb as standard, which produces a stronger or weaker structure depending on the type of wood and makes the surface less sensitive to scratches.  Alternatively, a smooth sanding _gs can be carried out, or on request a bandsaw cut _grimitated.

    Structure

    _gb Brushed

    Treatment


    Depending on the type of wood, the optional application of a surface treatment is possible ex works. Individual colour finishes are always sampled for coordination. For elements in individual lengths, colour treatment is limited to max. 5 m length.

    Treatment

    _buv UV-protection stain 

  • Schematische Darstellung einer Wandverkleidung made of LIGNO® aus Holz

    LIGNO® Acoustic light  |  Wall cladding 

    Product code: LIGNO® Acoustic light 3S_33_a70g_625-12-4_WTL_gb_buv
    Wood type


    Various wood species are available for the visible layer. For quality reasons, individual wood species cannot be configured for all profiles; for technical reasons, surface treatments are excluded for some wood species.

    Wood type

    _WTL Silver fir knotless, patterned 

    Profile


    The visible layer is profiled with joints. The code for profiling indicates in millimetres: Element width, strip width (rounded, from/to if applicable) and joint width (rounded) as well as a letter identification for variants, e.g. with chamfered strip edges or with additional height gradation. 

    Note: Some profiles indirectly cause exclusions for other configuration options.

    Profile 

    _625-12-4 Slat profile 

    Structure


    The face is subjected to a brushing _gb as standard, which produces a stronger or weaker structure depending on the type of wood and makes the surface less sensitive to scratches.  Alternatively, a smooth sanding _gs can be carried out, or on request a bandsaw cut _grimitated.

    Structure

    _gb Brushed

    Treatment


    Depending on the type of wood, the optional application of a surface treatment is possible ex works. Individual colour finishes are always sampled for coordination. For elements in individual lengths, colour treatment is limited to max. 5 m length.

    Treatment

    _buv UV-protection stain 

    Room acoustics


    If the soffit of the element is to have a good sound-absorbing effect, the penultimate layer is configured as absorber _a50g. Otherwise, this layer is configured as a solid wood layer _a0.

    Room acoustics

    _a70g 70% Absorber

  • LIGNO® U*psi  |  Insulation joist

    Product code: LIGNO® U*psi F_n_300
    Insulation joist


    The lower the U-value of a component and the lower the psi value of the details, the less heat is lost. This is precisely where the U*psi® cross-laminated timber insulating uprights from Lignotrend come into effect: They implement high insulating thicknesses in natural timber and minimise thermal bridges.

    Insulation joist

    Fleece as chamber separation

Reference-related

Downloads

Project participants

  • Da-Di-Werk

    Client

    Eigenbetrieb für Gebäude- und Umweltmanagement des Landkreises Darmstadt-Dieburg
    Roßdörfer Str. 106
    64409 Messel

     

    www.da-di-werk.de

  • ramona buxbaum architekten

    Architect

    Forsthaus am Jagdschloss
    Kranichsteiner Str. 258
    64289 Darmstadt
     

    www.ramonabuxbaum.de

  • Holzbau Amann GmbH

    Execution

    Albtalstraße 1
    79809 Weilheim

    www.holzbau-amann.de

  • Eicken Architekturfotografie

    Photographer

    Mühltal

  • Related references

      Largest school in France

      No one misses the new school complex at the centre of the revitalised Pasteur district of Limeil-Brévannes...

      94450 FR-Limeil-Brévannes 

      View
        titletitletitletitletitletitletitle

      Heilbronn Education Campus

      To deal with a building task and with the opportunities and conditions of the location...

      74081 Heilbronn 

      View
        titletitletitletitletitletitle