Sonnenhöhe retirement home in Breitnau

Climate-neutral building complexes with sustainable construction and energy concept

The new retirement and nursing home in Breitnau consists of two multi-storey buildings, which are grouped around a wind-protected courtyard and thus interpret the regional „homestead“ building type in a modern way. Both the support structure and the façades are entirely timber constructions. The café, which is open to the public, is the communicative heart of the house. Exposed wood and bright colours create a friendly atmosphere. Acoustic ceilings in knotless silver fir not only ensure naturalness, but also good room acoustics – so that animated chatter does not become a stress factor. 

Configuration overview

Components used

  • LIGNO® Rippe Q3  |  Ceiling component

    Product code: LIGNO® Rippe Q3_310-450_r0_s0_z80_p0_a50g_625-12-4_WTE_gb_b0
    Installation top


    Whether the element is open or closed at the top is determined by the area of application. If, for example, the element is to be filled with fill on site as a storey ceiling or roof terrace (LIGNO® Rippe Q3-x), its cavities are open at the top (feature _r0). To guide pipes at the top of the element, a cross grid (_r25, _r50) can be added to some superstructures. For roof superstructures, there is usually a flat closed finish _rg0 (LIGNO® Block Q-x, LIGNO® Block Q3-x or corresponding versions of LIGNO® Acoustic classic).

    Installation top

    _r0 Open, without cross grid

    Statics


    The height of the load-bearing webs of the element is variable and determined according to static requirements from load and span. Within the framework of this configurator, the selection is limited to four height ranges. A more precise definition is made later during pre-dimensioning or verification with the LTB-x calculation programme. Bulk volume and/or necessary space for installations can also be decisive for the height.

    Statics 

    _310-450 Large span

    Fire resistance


    If fire protection is required, an additional layer is added below the web area (for elements with strip profiles _z26, _z53, _z80, for elements with board profiles Akustik klassik _k50g). Their height determines the fire resistance duration of the cross-section from 30 to 90 minutes. The fire resistance must be statically verified. If there are no requirements, the standard versions _z0 or _k50l are to be selected.

    Fire resistance

    _z80 REI 90 Fire Resistant

    Cavity


    Panel designs with slat profiles and additional layer can be configured with an additional cavity (_p26, _p53) below the additional layer for installation guides, fixtures or to improve sound absorption. Cables laid there then do not penetrate the fire-protection layer. If required, the cavity is filled with insulating material (_p26mw, _p26ha) to improve acoustic absorption. If no cavity is necessary, the characteristic _p0 is selected.

    Cavity

    _p0 No cavity

    Room acoustics


    If the soffit of the element is to have a good sound-absorbing effect, the penultimate layer is configured as absorber _a50g. Otherwise, this layer is configured as a solid wood layer _a0.

    Room acoustics

    _a50g 50 % Absorber

    Profile


    The visible layer is profiled with joints. The code for profiling indicates in millimetres: Element width, strip width (rounded, from/to if applicable) and joint width (rounded) as well as a letter identification for variants, e.g. with chamfered strip edges or with additional height gradation.

     

    Note: Some profiles indirectly cause exclusions for other configuration options.

    Profile 

    _625-12-4 Slat profile

    Wood type


    Various wood species are available for the visible layer. For quality reasons, individual wood species cannot be configured for all profiles; for technical reasons, surface treatments are excluded for some wood species.

    Wood type

    _WTE Silver fir, economy

    Structure


    The face is subjected to a brushing _gb as standard, which produces a stronger or weaker structure depending on the type of wood and makes the surface less sensitive to scratches. Alternatively, a smooth sanding _gs can be carried out, or on request a bandsaw cut _grimitated.

    Structure

    _gb Brushed

    Treatment


    Depending on the type of wood, the optional application of a surface treatment is possible ex works. Individual colour finishes are always sampled for coordination. For elements in individual lengths, colour treatment is limited to max. 5 m length.

    Treatment

    _b0 Untreated

  • LIGNO® Block Q  |  Roof component

    Product code: LIGNO® Block Q_310-450_rg0_s0_z26_p0_a0_625-12-4_WTE_gb_b0
    Installation top


    Whether the element is open or closed at the top is determined by the area of application. If, for example, the element is to be filled with fill on site as a storey ceiling or roof terrace (LIGNO® Rippe Q3-x), its cavities are open at the top (feature _r0). To guide pipes at the top of the element, a cross grid (_r25, _r50) can be added to some superstructures. For roof superstructures, there is usually a flat closed finish _rg0 (LIGNO® Block Q-x, LIGNO® Block Q3-x or corresponding versions of LIGNO® Acoustic classic).

    Installation top

    _rg0 Closed, without cross grid

    Statics


    The height of the load-bearing webs of the element is variable and determined according to static requirements from load and span. Within the framework of this configurator, the selection is limited to four height ranges. A more precise definition is made later during pre-dimensioning or verification with the LTB-x calculation programme. Bulk volume and/or necessary space for installations can also be decisive for the height.

    Statics

    _310-450 Large span

    Fire resistance


    If fire protection is required, an additional layer is added below the web area (for elements with strip profiles _z26, _z53, _z80, for elements with board profiles Akustik klassik _k50g). Their height determines the fire resistance duration of the cross-section from 30 to 90 minutes. The fire resistance must be statically verified. If there are no requirements, the standard versions _z0 or _k50l are to be selected.

    Fire resistance

    _z26 REI 30 Fire resistance

    Cavity


    Panel designs with slat profiles and additional layer can be configured with an additional cavity (_p26, _p53) below the additional layer for installation guides, fixtures or to improve sound absorption. Cables laid there then do not penetrate the fire-protection layer. If required, the cavity is filled with insulating material (_p26mw, _p26ha) to improve acoustic absorption. If no cavity is necessary, the characteristic _p0 is selected.

    Cavity

    _p0 No cavity

    Room acoustics


    If the soffit of the element is to have a good sound-absorbing effect, the penultimate layer is configured as absorber _a50g. Otherwise, this layer is configured as a solid wood layer _a0.

    Room acoustics

    _a0 Without absorber

    Profile


    The visible layer is profiled with joints. The code for profiling indicates in millimetres: Element width, strip width (rounded, from/to if applicable) and joint width (rounded) as well as a letter identification for variants, e.g. with chamfered strip edges or with additional height gradation.
     

    Note: Some profiles indirectly cause exclusions for other configuration options.

    Profile 

    _625-12-4 Slat profile

    Wood type


    Various wood species are available for the visible layer. For quality reasons, individual wood species cannot be configured for all profiles; for technical reasons, surface treatments are excluded for some wood species.

    Wood type

    _WTL Silver fir knotless, patterned

    Structure


    The face is subjected to a brushing _gb as standard, which produces a stronger or weaker structure depending on the type of wood and makes the surface less sensitive to scratches. Alternatively, a smooth sanding _gs can be carried out, or on request a bandsaw cut _grimitated.

    Structure

    _gb Brushed

    Treatment


    Depending on the type of wood, the optional application of a surface treatment is possible ex works. Individual colour finishes are always sampled for coordination. For elements in individual lengths, colour treatment is limited to max. 5 m length.

    Treatment

    _b0 Untreated

  • LIGNO® Akustik light  |  Ceiling cladding 

    Product code: LIGNO® Akustik light 3S_33_a70g_625-12-4_WTE_gb_bo
    Room acoustics


    If the soffit of the element is to have a good sound-absorbing effect, the penultimate layer is configured as absorber _a50g. Otherwise, this layer is configured as a solid wood layer _a0.

    Room acoustics

    _a70g 70 % Absorber

    Profile


    The visible layer is profiled with joints. The code for profiling indicates in millimetres: Element width, strip width (rounded, from/to if applicable) and joint width (rounded) as well as a letter identification for variants, e.g. with chamfered strip edges or with additional height gradation.
     

    Note: Some profiles indirectly cause exclusions for other configuration options.

    Profile 

    _625-12-4 Slat profile

    Wood type


    Various wood species are available for the visible layer. For quality reasons, individual wood species cannot be configured for all profiles; for technical reasons, surface treatments are excluded for some wood species.

    Wood type

    _WTE Silver fir, economy

    Structure


    The face is subjected to a brushing _gb as standard, which produces a stronger or weaker structure depending on the type of wood and makes the surface less sensitive to scratches. Alternatively, a smooth sanding _gs can be carried out, or on request a bandsaw cut _grimitated.

    Structure

    _gb Brushed

    Treatment


    Depending on the type of wood, the optional application of a surface treatment is possible ex works. Individual colour finishes are always sampled for coordination. For elements in individual lengths, colour treatment is limited to max. 5 m length.

    Treatment

    _b0 Untreated

Reference-related

Downloads

Project participants

  • fuchs.maucher.architekten.bda

    Architect

    Am Kraftwerk 4

    79183 Waldkirch

     

    fmarchitekten.de/

  • Holzbau Bruno Kaiser GmbH

    Execution

    Gewerbegebiet Gässle 7
    79872 Bernau im Schwarzwald

    www.holzbau-bruno-kaiser.de

  • GRANACHER

    Photographer

    Hofwiese 10
    79809 Weilheim

     

    www.simplexxx.de

  • Related references