Choose your language

WFB Mosaik

Noble silver fir creates a homely and friendly ambience 

The shingle-clad workshop building has a public forecourt, a more intimate work yard and a small shop where the products produced in the fields next door are marketed directly. The striking roof terrace appears as if cut out of the volume of the cube and illuminates a large common room. Here, the surface of the large span CLT roof in noble silver fir provide a very homely and friendly ambience. 

Configuration overview 

components used

  • LIGNO® Block Q3  | Roof component 

    Product code: LIGNO® Block Q3_310-450_rg0_s0_z26_p0_a50g_625-12-4_WTL_gb_buv
    Installation top

     

    Whether the element is open or closed at the top is determined by the area of application. If, for example, the element is to be filled with fill on site as a storey ceiling or roof terrace (LIGNO® RIppe Q3-x), its cavities are open at the top (feature _r0). To guide pipes at the top of the element, a cross grid (_r25, _r50) can be added to some superstructures. For roof superstructures, there is usually a flat closed finish _rg0 (LIGNO® Block Q-x, LIGNO® Block Q3-x or corresponding versions of LIGNO® Acoustic classic).

    Installation top

    _rg0 Closed, without cross grid

    Statics

     

    The height of the load-bearing webs of the element is variable and determined according to static requirements from load and span. Within the framework of this configurator, the selection is limited to four height ranges. A more precise definition is made later during pre-dimensioning or verification with the LTB-x calculation programme. Bulk volume and/or necessary space for installations can also be decisive for the height.

    Statics

    _310-450 Large span

    Fire resistance

     

    If fire protection is required, an additional layer is added below the web area (for elements with strip profiles _z26, _z53, _z80, for elements with board profiles Akustik klassik _k50g). Their height determines the fire resistance duration of the cross-section from 30 to 90 minutes. The fire resistance must be statically verified. If there are no requirements, the standard versions _z0 or _k50l are to be selected.

    Fire resistance

    _z26 REI 30 Fire restistant

    Cavity

     

    Panel designs with strip profiles and additional layer can be configured with an additional cavity (_p26, _p53) below the additional layer for installation routing, fixtures or to improve sound absorption.Cables laid there then do not penetrate the fire-protective layer. If required, the cavity is filled with insulating material (_p26mw, _p26ha) to improve acoustic absorption. If no cavity is necessary, the characteristic _p0 is selected.

    Cavity

    _p0 No cavity

    Room acoustics

     

    If the soffit of the element is to have a good sound-absorbing effect, the penultimate layer is configured as absorber _a50g. Otherwise, this layer is configured as a solid wood layer _a0.

    Room acoustics

    _a50g Integrated absorber

    Profile 

     

    The visible layer is profiled with joints. The code for profiling indicates in millimetres: Element width, strip width (rounded, from/to if applicable) and joint width (rounded) as well as a letter identification for variants, e.g. with chamfered strip edges or with additional height gradation.

     

    Note: Some profiles indirectly cause exclusions for other configuration options.

    Profile 

    _625-12-4 Slat profile

    Wood type

     

    Various wood species are available for the visible layer. For quality reasons, individual wood species cannot be configured for all profiles; for technical reasons, surface treatments are excluded for some wood species.

    Wood type

    _WTL Silver fir knotless, patterned

    Treatment 

     

    Depending on the type of wood, the optional application of a surface treatment is possible ex works. Individual colour finishes are always sampled for coordination. For elements in individual lengths, colour treatment is limited to max. 5 m length.

    Treatment 

    _buv UV-protection stain

    Structure

     

    The face is subjected to a brushing _gb as standard, which produces a stronger or weaker structure depending on the type of wood and makes the surface less sensitive to scratches.  Alternatively, a smooth sanding _gs can be carried out, or on request a bandsaw cut _grimitated.

    Structure

    _gb Brushed

  • LIGNO® Block Q3  | Roof component 

    Product code: LIGNO® Block Q3_310-450_rg0_s0_z80_p0_a50g_625-12-4_WTL_gb_buv
    Installation top

     

    Whether the element is open or closed at the top is determined by the area of application. If, for example, the element is to be filled with fill on site as a storey ceiling or roof terrace (LIGNO® Rippe Q3-x), its cavities are open at the top (feature _r0). To guide pipes at the top of the element, a cross grid (_r25, _r50) can be added to some superstructures. For roof superstructures, there is usually a flat closed finish _rg0 (LIGNO® Block Q-x, LIGNO® Block Q3-x or corresponding versions of LIGNO® Acoustic classic).

    Installation top

    _rg0 Closed, without cross grid

    Statics 

     

    The height of the load-bearing webs of the element is variable and determined according to static requirements from load and span. Within the framework of this configurator, the selection is limited to four height ranges. A more precise definition is made later during pre-dimensioning or verification with the LTB-x calculation programme. Bulk volume and/or necessary space for installations can also be decisive for the height.

    Statics 

    _310-450 Large span

    Ffire resistance

     

    If fire protection is required, an additional layer is added below the web area (for elements with strip profiles _z26, _z53, _z80, for elements with board profiles Akustik klassik _k50g). Their height determines the fire resistance duration of the cross-section from 30 to 90 minutes. The fire resistance must be statically verified. If there are no requirements, the standard versions _z0 or _k50l are to be selected.

    Ffire resistance

    _z80 REI 90 Fire resistant

    Cavity 

     

    Panel designs with strip profiles and additional layer can be configured with an additional cavity (_p26, _p53) below the additional layer for installation routing, fixtures or to improve sound absorption.Cables laid there then do not penetrate the fire-protective layer. If required, the cavity is filled with insulating material (_p26mw, _p26ha) to improve acoustic absorption. If no cavity is necessary, the characteristic _p0 is selected.

    Cavity 

    _p0 No cavity

    Room acoustics

     

    If the soffit of the element is to have a good sound-absorbing effect, the penultimate layer is configured as absorber _a50g. Otherwise, this layer is configured as a solid wood layer _a0.

    Room acoustics

    _a50g Integrated aborber

    Profile 

     

    The visible layer is profiled with joints. The code for profiling indicates in millimetres: Element width, strip width (rounded, from/to if applicable) and joint width (rounded) as well as a letter identification for variants, e.g. with chamfered strip edges or with additional height gradation.

     

    Note: Some profiles indirectly cause exclusions for other configuration options.

    Profile 

    _625-12-4 Slat profile

    Wood type

     

    Various wood species are available for the visible layer. For quality reasons, individual wood species cannot be configured for all profiles; for technical reasons, surface treatments are excluded for some wood species.

    Wood type

    _WTL Silver fir knotless, patterned

    Treatment 

     

    Depending on the type of wood, the optional application of a surface treatment is possible ex works. Individual colour finishes are always sampled for coordination. For elements in individual lengths, colour treatment is limited to max. 5 m length.

    Treatment 

    _buv UV-protection stain

    Structure

     

    The face is subjected to a brushing _gb as standard, which produces a stronger or weaker structure depending on the type of wood and makes the surface less sensitive to scratches.  Alternatively, a smooth sanding _gs can be carried out, or on request a bandsaw cut _grimitated.

    Structure

    _gb Brushed

Reference-related 

Downloads

Project participants

  • Bernd Zimmermann Architekten

    Architect

    Rheinlandstraße 10
    71636 Ludwigsburg
     

    www.german-architects.com

  • Zimmerermeister Karsten Jantzen GmbH

    Execution

    Lambrechtshäger Straße 7
    18069 Lambrechtshagen

    www.zimmerermeister-jantzen.de

  • Valentin Wormbs Fotografie

    Photographer
  • Lignotrend Produktions GmbH

    Photographer

    Landstraße 25
    79809 Weilheim

     

    www.lignotrend.de

  • Related references

      Refuge du Goûter 

      Probably the highest building with Lignotrend elements is the four-storey, energy self-sufficient Refuge du Goûter...

      74170 FR-Saint-Gervais-les-Bains 

      View
        titletitle

      Mensa "Halle aux farines" in Paris

      The industrial building once served to store flour from the Grands Moulins de Paris. At the beginning of the...

      75013 FR-Paris 

      View
        titletitletitletitletitle